NEW!

DS-2TD2667T-15/P HIKVISION

(the price includes VAT)

Bispectral Bullet Thermal & Optical Network Camera
Resolution 640 x 512, 17 µm, VOx UFPA, NETD < 35 mK (25 °C, F# = 1.0)
Temperature exception alarm to prevent fire, -20 °C to 550 °C (-4 °F to 1022 °F), Max. (± 2 °C, ± 2%)
Image processing technology: linear, histogram, self-adaptive thermal function AGC, DDE, 3D DNR
Fire detection algorithm

SKU: DS-2TD2667T-15/P HIKVISION Category:

Description

Hikvision DS-2TD2667T-15/P Thermographic Thermal & Optical Bi-Spectrum Network Bullet Camera can be applied to substations, hydropower stations, waste incineration plants, manufacturing workshops, etc. The accurate temperature measurement device sends temperature exception alarms for loss prevention.
 640 x 512 resolution, 17 μm, VOx UFPA, NETD < 35 mK (25 °C, F# = 1.0)
 Temperature exception alarm for fire prevention, -20 °C to 550 °C (-4 °F to 1022 °F), Max. (± 2 °C, ± 2%)
 Image processing technology: linear, histogram, self-adaptive thermal AGC mode, DDE, 3D DNR
 Fire detection algorithm

Specification
Thermal Module
Image Sensor Vanadium Oxide Uncooled Focal Plane Arrays
Resolution 640 × 512
Pixel Pitch 17 μm
Spectral Range 8 μm to 14 μm
NETD <35 mk (25 °C, F# = 1.0)
Focal Length 15 mm
IFOV 1.13 mrad
Field of View 42.5° × 33.6° (H × V)
Min. Focusing Distance 2.5 m
Aperture F 1.0
Digital Zoom ×2, ×4, ×8
Optical Module
Image Sensor 1/2.7″ Progressive Scan CMOS
Resolution 2688 × 1520
Min. Illumination Color: 0.0089 Lux @ (F1.6, AGC ON), B/W: 0.0018 Lux @ (F1.6, AGC ON)
Shutter Speed 1 s to 1/100,000 s
Focal Length 4 mm
Field of View 84° × 44.8° (H × V)
Aperture (Range) F 1.6
WDR 120 dB
Image Effect
Bi-spectrum Image Fusion Display the details of optical channel on thermal channel
Picture in Picture Display partial image of thermal channel on the full screen of optical channel
Target Coloration Yes. Supported in white hot and black hot mode.
Illuminator
IR Distance Up to 40 m
IR Intensity and Angle Automatically adjusted
Smart Function
VCA
4 VCA rule types (line crossing, intrusion, region entrance, and region exiting),
up to 8 VCA rules in total.
Temperature Measurement
3 temperature measurement rule types, 21 rules in total (10 points, 10 areas,
and 1 line).
Temperature Range – 20 °C to 550 °C (- 4 °F to 1022 °F)
Temperature Accuracy Max (± 2 °C, ±2 %)
Fire Detection Dynamic fire detection, up to 10 fire points detectable.

TOP
Home
Account
Cart
Search